'Influence of Draft Tube Diameter on Operation Behavior of Air Lift Loop Reactors

Authors

  • Ali Abdul-Rahman Al-Azzi Department of Chemical Engineering/ University of Technology
  • Laith S. S. Al-Kuffe Department of Chemical Engineering/ University of Technology

Abstract

The ratio of draft tube to reactor diameters is of decisive importance for the operation behavior of air lift loop reactors. The influence of draft tube geometry was investigated with respect to oxygen mass transfer and mixing time. The diameter ratio was varied between 0.33 and 0.80. The measurements were performed in two loop reactors with liquid capacities of 11.775 and 26.49 liters using aqueous with solutions of different coalescence behavior. The results show that there is no single diameter ratio which would produce most favorable conditions for the two process parameters. With respect to the more important requirements of aerobic cultures, i.e high oxygen mass transfer and efficient mixing, a diameter ratio between 0.5 and 0.6 is recommended. If high liquid velocities in the draft tube are required a ratio of 0.6 should be used.

Downloads

Download data is not yet available.

References

[1] Degaleesam S,Dudukavic M ,pan Y Experimental study of gas induced liquid flow structures in bublle columns .AICHE J 2001;97:1913-31.
[2] Onken , U, Weiland , P. Adv . Biotechnol .proc 1(1983) p.67.
[3] Blenke , Hm Adv. Biochem . Eng 13 (1979) p .121.
[4] Belfield , A, R, thesis , Univ, Maryland 1976.
[5] Hines , D. A. , DECREMA-MONOGR-82(1978)P.55.
[6] Leistner, G, Muiler , G, Sell , G ,Bouer, A , Chem –Ing.Tech . 51(1979)p-288.
[7] De Neverss, N, AICHE J . 41(1968)P.222.
[8] Cooper, P. G.Sliver ,R,S , Boyle ,J,P. In-single –call protein 11 (Tannenbaum, S. R. Wany , D,I,C. ECTS)P.454,MIT-press,Cambridge, mass, 1975.
[9] Blenke, H. Bohner , K., Scuster, 8., VDI BER (ver . Dtsch . ing)(1965) Nr.96,p.113.
[10] Blenke, H. Bohner , K., Pfeiffer , W, chem. –ing-Tech.43(1971) p.10.
[11] Nicklin , D. J, chem. Eng . sci, 17 (1962) p.693.
[12] Weiland , p. , Onken , U . Ger , Chem. , Eng 4 (1981) p. 174.
[13] Heinecken . F. H . , Biotechoal . Bioeng 12(1970)P.145.
[14] Kridhna R , De Stwart JWA , Henneph of DD , Ellen Berger J . Hoefsloot HCJ , Influence of increased gas density on hydndynamic of bubble column reactors –AICHE J 1994;40:112-9.
[15] K. Koude. H. Serto and SHNJI IWAMOTO Gas hold up and volumetric liquid phase mass transfer coefficient in bubble column with draft tube and with gas dispersion into annulus . J, Chem. Eng. Jph . 1983;16;407-412.
[16] Hiby , J.W , definition and measurement of the degree of mixing in liquid mixtures , Int . Chem . Eng (1981);21(2):197-204.

Downloads

Published

2010-06-01

How to Cite

’Influence of Draft Tube Diameter on Operation Behavior of Air Lift Loop Reactors. (2010). Al-Khwarizmi Engineering Journal, 6(2), 21-32. https://alkej.uobaghdad.edu.iq/index.php/alkej/article/view/486

Publication Dates